1. Before installing the pressure reducer, slightly open the cylinder
valve to blow down the dirt to prevent dust and moisture from entering
the pressure reducer before installing the pressure reducer. When
opening the cylinder valve, the operator should not stand in front of
the outlet of the cylinder valve to prevent the sudden rush of
high-pressure gas from hurting people.
2. The pressure
regulator screw should be loosened before opening the cylinder valve.
When opening the cylinder valve, it should be done slowly and not too
hard to prevent high pressure gas from damaging the pressure reducer and
pressure gauge.
3. After opening the cylinder valve,
check for air leakage in all parts. Whether the pressure gauge is
working properly, the hose should be connected after checking.
4.
When adjusting the working pressure, the pressure regulating screw
should be rotated slowly. To prevent high-pressure gas from breaking
diaphragm or damaging low-pressure meter
5. Pressure
reducer should not be contaminated with grease. If there is any grease,
it must be controlled and cleaned before it can be used.
6. In the course of using the pressure reducer, if freezing occurs, thaw it with hot water or steam, and do not bake it by fire.
7.
When stopping working, the bottle valve should be closed and the gas in
the pressure reducer should be slowly exhausted, and the pressure
regulating spring should be kept in its own state.
8.
Pressure reducers must be checked regularly and pressure gauges must be
checked regularly to ensure reliable pressure regulation and accurate
reading.
9. Oxygen and acetylene decompressors are not interchangeable
10. The working pressure of 10 acetylene depressor should not be greater than 0.1 MPa